Cảm biến oxy hãng Nouva Đức
Cảm biến oxy máy thở
Cảm biến oxy máy gây mê
Manufacturer/Model |
OEM Sensor/Machine |
Nuova Sensors |
Aeomed® |
Aeon 7200, 7400A |
E-77/0 |
Airshields (Dräger)® |
6735142 |
E-17/J |
Airshields (Dräger)® |
6736140 |
E-55/0 |
Airshields® (Dräger) C100 |
specify monitor and oxygen cell |
|
Airshields (Dräger)® |
Infant Incubator Isolette C2000, C2000e, 8000, 8000plus (OEM sensor MU24903 double pack |
E-17/A2/2pc |
Air Liquide Healthcare® |
Xtend Ventilator, Monnal T60,T75 OEM sensor YR0049700 |
E-17/M |
Akkutronik® |
Monsoon III, Fabian, Fabian+ |
E-17/A4 |
Allied Healthcare® (B+F Medical) |
65004 |
E-33/0 |
Alpha Med® |
|
E-17/J |
Analystical Industrie® |
AII2000M/A monitors |
E-60/0 |
Analystical Industries® |
PSR-11-75-KE1, KE2, KE4, KE6, KE8 |
n/a |
Analytical Industrie® |
PSR-11-915 |
E-15/0 |
Analytical Industries® |
PSR-II-58 |
E-47/0 |
Analytical Industries® |
PSR-11-55 |
E-55/0 |
Analytical Industries® |
PSR-11-77 |
E-77/0 |
Analytical Industries® |
PSR-11-95/4 |
E-15/4 |
Analytical Industries® |
PSR-11-15/2i |
E-15/2 |
Analytical Industries® |
PSR-11-917-M1 and -MH |
E-17/A2 |
Analytical Industries® |
PSR-11-917-M |
E-16/0 |
Analytical Industries® |
PSR-11-917-M2 |
E-17/M |
Analytical Industries® |
PSR-11-917-J1 |
E-25/0 |
Analytical Industries® |
PSR-11-917-J6 |
E-17/J |
Analytical Industries® |
PSR-11-33 |
E-33/0 |
Analytical Industries® |
PSR-11-33-2 |
ask Nuova |
Analytical Industries® |
PSR-11-60-03 |
E-77/0S |
Analytical Industries® |
PSR-11-77/0 |
E-77/0 |
ATOM® |
100 & 101 dual incubator, (ound cap, double pack) |
E-17/A2A |
ATOM® |
OX-60 |
E-15/5 |
ATOM® |
2000, 2100 Incubator, 2100G, V220 (round conn.) |
E-17/A2A |
ATOM® |
V2200 (round connector) |
E-17/A2A |
BCI® |
R-17 |
E-17/J |
Bertucci® |
T1/T2 |
E-33/0 |
Bio Tek® |
X74223 |
E-33/0 |
Biomed® |
Sensor 4434 |
E-14/S |
Bird® (see Viasys) |
AVEA |
E-17/C |
Bird® (see Viasys) |
Sentry and Senty I |
E-25/0 |
BMD® |
10006 |
E-17/J |
BREAS® (GE®) |
Vivo 50 |
E-17/J |
BURKE & BURKE® |
OOM102 |
E-17/A2 |
BURKE & BURKE® |
OOM104 |
E-8000 |
BURKE & BURKE® |
OOM201 |
E-15/2 |
CAREFUSION® (see also Versamed, Bird, Viasys) |
|
|
Ceramatec® |
CAG-14 |
E-09/0 |
Ceramatec® |
CAG-1 |
E-15/0 |
Ceramatec® |
CAG-11 |
E-15/2 |
Ceramatec® |
CAG-10 |
E-15/4 |
Ceramatec® |
CAG-13 |
E-15/5 |
Ceramatec® |
CAG-12 |
E-17/M |
Ceramatec® |
CAG-19 |
E-33/0 |
Ceramatec® |
CAG-18 |
E-33/1 |
Ceramatec® |
CAG-9 |
E-55/0 |
Ceramatec® |
CAG-17 |
E-77/0 |
Cheiron® |
CAG-18 |
E-33/1 |
City Technologies® |
MOX-10 |
E-11/0 |
City Technologies® |
MOX-01 |
E-17/A2 |
City Technologies® |
MOX-02 |
E-15/5 |
City Technologies® |
MOX-09 |
E-17/M |
City Technologies® |
MOX-04 |
E-77/0 |
City Technologies® |
MOX-03 |
E-77/OS |
City Technologies® |
MOX-06 |
E-15/0 |
Comen® |
MOX-03 |
E-77/OS |
Covidien® (see Puritan Bennett®) |
|
|
Criticare® |
644 oxygen cell |
E-17/A2 |
Criticare® |
8100Poet Plus, 8500 Poet, 8500 Poet IQ, IQ2 |
E-17/A2 |
Dameca® |
Alphamed |
E-17/J |
Datascope® |
E-17/A2A |
|
DP Medical® |
MVA210 |
E-15/2 |
Dräger® (see airshields) |
Inubator Isolette 2000/8000/8000plus Dräger cell Mu24903 (double pack 2 pc) |
E-17/A2 (double pack) |
Draeger® |
Original 6850930 |
n/a |
Draeger® |
6803290 |
E-15/0 |
Draeger® |
Incubator 8000 old model (see also Airshields) |
E-8000 |
Draeger® |
E-15/2 |
|
Draeger® Narcomed 1A,2,2B,3,4 |
6850645 oxygen cell |
E-15/2 |
EME®, |
Infant Ventilator |
E-17/M |
EnviteC® |
OOM204 |
E-17/A4 |
EnviteC® |
OOM202-1 |
E-17/J |
EnviteC® |
OOM202-2 |
E-09/0 |
EnviteC® |
OOM202-2S |
E-11/0 |
EnviteC® |
OxiQuant B |
E-15/5 |
EnviteC® |
OxiQuant RM |
E-15/0 |
EnviteC® |
OOM201 |
E-15/2 |
EnviteC® |
OOM102-1 |
E-15/5 |
EnviteC® |
OxiQuant M |
E-15/5 |
EnviteC® |
OOM101 |
E-15/0 |
EnviteC® |
OOM102 |
E-17/A2 |
EnviteC® |
OOM102-C |
E-17/A2 |
EnviteC® |
OOM103 |
E-17/A2 |
EnviteC® |
OOM103-1 |
E-17/J |
EnviteC® |
OOM103-1M |
E-25/0 |
EnviteC® |
OOM202 |
E-17/M |
EnviteC® |
OOM107 |
E-33/0 |
EnviteC® |
OOM107-2 |
E-33/1 |
EnviteC® |
OOM105 |
E-77/0 |
EnviteC® |
OOM104 |
E-8000 |
EnviteC® |
OOM106 |
E-17/A2A |
EnviteC® |
OOM110 |
E-15/4 |
eVent Medical |
Inspiration LS |
E-17/M |
F. Stephan® |
Stefanie |
E-11/0 |
F. Stephan® |
OOM101 |
E-15/0 |
F. Stephan® |
ARTEC |
E-15/5 |
F. Stephan® |
Alia part no. 13006001 (M-11) |
E-11/0 |
F. Stephan® |
Christina 1107600009 Vent. |
E-17/J |
Fraser Harlake® |
E-33/0 |
|
Fresenius® |
X74223 |
E-33/0 |
Ginevri Italy® |
Figaro 25 sensor |
not available |
GE/Marquette® |
R-22 |
E-17/A2 |
GE®/BREAS® |
see under BREAS |
|
GE/Ohmeda® |
see under Ohmeda |
|
Hamilton® |
Amadeus, Veolar |
E-33/0 |
Hamilton® |
Oxygen cell HM-12, Raphael, Galileo, Arabella, Aladdin |
E-17/M |
Hamilton® |
Oxygen cell HM-10 |
E-15/0 |
Hamilton® |
Oxygen cell HM-13, HM-14 |
E-15/2 |
Hamilton ® |
Oxygen cell HM-12 |
E-17/A2 |
Hamilton® |
Oxygen cell HM-11 |
E-17/J |
Hamilton® |
Oxygen cell HM-03 |
E-77/0 |
Hamilton® |
G5 |
E-17/A2 |
Heinen und Loewenstein® |
OOM102 |
E-17/A2 |
Heinen und Loewenstein® |
Leon |
n/a |
Henleys® |
5556 |
E-17/A2 |
Henleys® |
5567 |
E-17/J |
Henleys® |
5569 |
E-33/0 |
Heyer® |
Pocket O2 |
E-33/0 |
Hill-ROM® (see Airshields®) |
|
E-17/A2 |
Hudson® |
5800, 5801, 5803 |
E-47/0 |
Hudson® |
5556 |
E-15/0 |
Hudson® |
5557, V-14 |
E-15/2 |
Hudson® |
5566, V-12 |
E-17/A2 |
Hudson® |
5567, V-11 |
E-17/J |
Hudson® |
5568 C1, V-01 |
E-33/0 |
Hudson® |
5558, V-03 |
E-77/0 |
Hudson® |
5565 |
ask Nuova |
Hudson® |
5569, V-02, 5525, 5528, 5529, 5550, 5552 |
E-33/0 |
Hudson® |
5500, V-05, 5557, 6477, 5590, 5595, 5584 |
E-55/0 |
IMED® |
810/825 |
E-33/0 |
Infrasonics® |
Adult Star, 60116 |
E-17/M |
Integral Process® |
all |
ask Nuova |
Invivo® |
9445 sensor, Precess 3160, Millenia 3500, 3155A |
E-17/J |
IT-Gambert® |
M-43 (double pack) |
E-43/0 |
IT-Gambert® |
M-25 |
E-25/0 |
IT-Gambert® |
M-16 |
E-16/0 |
IT-Gambert® |
M-15 |
E-15/5 |
IT-Gambert® |
M-14TB |
M-14TB |
IT-Gambert® |
M-14 |
E-14/0 |
IT-Gambert® |
M-14/ST |
E-14/S |
IT-Gambert® |
M-18T |
E-18/T |
IT-Gambert® |
M-12 |
E-17/A2 |
IT-Gambert® |
M-12/A |
E-17/A2A |
IT-Gambert® |
M-10 |
E-15/4 |
IT-Gambert® |
M-16HT |
E-16/HTT |
IT-Gambert® |
M-09 |
E-09/0 |
IT-Gambert® |
M-08 |
E-8000 |
IT-Gambert® |
M-07 |
E-77/0 |
IT-Gambert® |
M07/S |
E-77/OS |
IT-Gambert® |
M06 |
E-33/1 |
IT-Gambert® |
M05 |
E-33/0 |
IT-Gambert® |
M-04 |
E-17/M |
IT-Gambert® |
M-04C |
E-17/C |
IT-Gambert® |
M-03 |
E-17/J |
IT-Gambert® |
M-02/L2 |
E-15/2 |
IT-Gambert® |
M-01 |
E-15/0 |
Ivac® |
1200, 1225 |
E-33/0 |
Kontron® |
ABT5100 |
E-17/J |
Libra® |
OM500 |
E-33/0 |
Lifecare® |
PLV-100/102/37-079 |
E-17/J |
Maxtec® |
OM25AE/OM-25A Monitor, OM-25MEL |
E-75/7 |
Maxtec® |
Max-1 |
E-15/0 |
Maxtec® |
Max-7 |
E-15/5 |
Maxtec® |
Max-11 |
E-15/2 |
Maxtec® |
Max-10 |
E-15/4 |
Maxte®c |
Max-16 |
E-16/0 |
Maxtec® |
Max-41 |
E-16/0 |
Maxtec® |
Max-47 |
E-47/0 |
Maxtec® |
Max-48 |
E-60/0 |
Maxtec® |
Max-12A |
E-17/A2 |
Maxtec® |
Max-12C |
E-17/C |
Maxtec® |
Max-13 (CAG13) |
E-17/J |
Maxtec® |
Max-12, 22C |
E-17/M |
Maxtec® |
Max-13 |
M-14/TB |
Maxtec® |
Max-13C |
E-14/0 |
Maxtec® |
Max-13J |
M-14/TB |
Maxtec® |
Max 25E, Max-250 ESF, OM-A25 Analyzer, OM-25ME Monitor, OM-25MEL Monitor (exernal sensor) |
E-25/0 |
Maxtec® |
Max-125M |
E-16/0 |
Maxtec® |
Max-16 |
E-16/0 |
Maxtec® |
Max 250E |
E-75/7 |
Maxtec® |
Max-250A |
E-75/A |
Maxtec® |
Max-250K |
E-75/4 |
Maxtec® |
Max-250B |
E-75/6 |
Maxtec® |
Max250E/OM-25MEL Monitor |
E-75/9 |
Maxtec® |
Max-25E |
E-25/0 |
Maxtec® |
Max-19 (CAG19) |
E-33/0 |
Maxtec® |
Max-18 (CAG18) |
E-33/1 |
Maxtec® |
Max-9 |
E-55/0 |
Maxtec® |
Max-17 (CAG17) |
E-77/O |
Maxtec® |
Max-2 |
E-15/1 |
Maxtec® |
Max-3 |
E-77/OS |
Maxtec® |
Max-8 |
ask Nuova |
Maxtec® |
Max-15 (CAG15) |
ask Nuova |
Maxtec® |
Max-25/250/OM25 Analyzer |
E-75/1 |
Maxtec® |
Max-14 |
E-09/0 |
MEDEC®, Belgium |
M-03 sensor |
E-17/J |
Medigas® |
T-1/T-2 |
E-33/0 |
Megamed® |
M2 |
E-33/0 |
Megamed® |
M1 |
E-33/1 |
Mercury Medical® |
all |
ask Nuova |
Mindray® |
VT50 Ventilator |
E-77/0S |
Mindray® |
MOX-2 sensor with different sensor cap for WATO series |
E-15/5M |
Mindray® |
SV-series |
E-77/0S |
MSA® (Catalyst Resarch) |
E-15/0 also E-15/2 |
|
MSA® (Catalyst Research) |
710644 |
E-16/0 |
MSA® (Catalyst Research) |
E-17/M |
|
MSA® (Catalyst Research) |
478841, 485955 |
E-33/0 |
MSA® (Catalyst Research) |
485905, 655262 |
E-33/1 |
MSA® (Catalyst Research) |
655265 |
E-55/0 |
MSA® (Catalyst Research) |
804674 |
E-77/0 |
MSA® MiniOx 3000 |
|
E-15/5 |
MSA® MiniOx I, II, III, |
406931 |
E-17/J |
MSA® MiniOx IA |
806572 |
E-09/0 |
Newport® |
Ventilator 500, Wave Ventilator |
E-77/0 |
Newport® |
Ventilator e500 & E360Event, HT-70 |
E-75/9 currently n/a |
Newport® VM200 |
VM200 |
E-77/0 |
Newport® Wave Ventilator |
OM100, OM105 |
E-77/0 |
Nuova |
M-OA2003 Oxygen Monitor |
E-49/0 |
OES Medical® |
MOX-3 |
E-77/OS |
Ohmeda® (GE®) |
Giraffe (double pack) |
E-43/0 (2pcs) |
Ohmeda® (GE®) |
Oxygen sensor 0237-2034-700 |
E-15/0 |
Ohmeda® (GE®) Smart Vent 7900, 7100 Ventilator, Modulus SE, S-5 Espire, Aestiva, 3000/5, Aespira, |
Oxygen sensor 6050-004-110 |
E-15/4 |
Ohmeda® (GE®) Centiva S/5 |
Oxygen sensor 6051-0000-216 |
E-17/A2 |
Ohmeda® (GE®) |
Oxygen sensor 6051-0000-224 |
E-15/2 |
Ohmeda® (GE®) |
Oxygen sensor 6051-0000-217 |
E-17/J |
Ohmeda® (GE®) |
Oxygen sensor 6051-0000-222 |
E-17/M |
Ohmeda® (GE®) |
Oxygen sensor 6051-0000-219 |
E-77/0 |
Oxiquip® |
T-1/T-2 |
E-33/0 |
Oxitron® |
3710 |
E-15/2 |
Oxitron® |
3310 |
E-17/J |
Oxitron® |
3250 |
E-33/0 |
Oxitron® |
3050 |
E-33/1 |
Pacifitech® |
all |
ask Nuova |
Paragon Services® |
PS-2000 |
E-15/2 |
Paragon Services® |
PS-1000 |
E-15/0 |
Penlon® |
MOX-3 |
E-77/OS |
Penlon® |
58780 oxygen sensor |
E-15/5 |
Penlon |
MTS oxygen sensors |
E-77/0 |
Philips |
V680P |
E-14/S |
PPG Biomedical® Saracap |
504055-001 |
E-17/M |
PPG Biomedical®, Irisa |
505055-001 |
E-15/2 |
Puritan Bennett® 740/760/840, PB2000 TEST |
4-072214-0 |
E-16/0 |
Puritan Bennett® |
sensor PB10097559 |
E-75/13PB |
Puritan Bennett® 7820/7200 Vent, PB850 |
4-020933-00 |
E-17/J |
Puritan Bennett® 840 Ventilator (OLD MODEL) |
|
E-75/1 currently n/a |
Respironics® RESMED® |
Esprit/Lifecare 1001454, Wisperflow (see CARADYNE) Elisee 150/250 (lead free sensor) |
E-15/5 E-60/LF |
Schoch® Esprit/Lifecare |
T1/T2 |
E-33/0 |
Sechrist® 650 |
43170 |
E-77/0 |
Sensidyne® |
SV-26 |
E-09/0 |
Sensidyne® |
SV-14A |
E-15/0 |
Sensidyne® |
SV-20A |
E-15/4 |
Sensidyne® |
SV-11A |
E-17/J |
Sensidyne® |
SV-12A |
E-17/M |
Sensidyne® |
SV-25A |
E-25/0 |
Sensidyne® |
SV-01 |
E-33/0 |
Sensidyne® |
SV-02 |
E-33/1 |
Sensidyne® |
SV-03 |
E-77/0 |
Sensor Tec ®(BPR Medical®) |
ST-05 |
E-55/0 |
Sensor Tec® (BPR Medical®) |
ST-13 |
E-15/0 |
Sensor Tec® (BPR Medical®) |
ST-14 |
E-15/2 |
Sensor Tec® (BPR® Medical) |
ST-10 |
E-15/0 |
Sensor Tec® (BPR® Medical) |
ST-12 |
E-17/A2 |
Sensor Tec® (BPR Medical®) |
ST-11 |
E-17/J |
Sensor Tec® (BPR Medical®) |
ST-12, ST-04 |
E-17/M |
Sensor Tec® (BPR Medical®) |
ST-02 |
E-33/1 |
Sensor Tec® (BPR Medical®) |
ST-01 |
E-33/0 |
Sensor Tec® (BPR Medical®) |
ST-03 |
E-77/0 |
Shoch® |
T-1/T-2 |
E-33/0 |
SIARE® |
Morpheo, Perseo |
E17/J |
Siemens® |
9004979/6419332, Ventilators 900, 900C, 900D, 700, 710, 300, V710, 600 |
E-17/M |
Siriusmed |
R-30 |
E-17/A2 |
SLE® |
2000HFO/2000 older style Vent (2 pin connector) |
E-75/6 currently n/a |
SLE® |
4000/5000 Vent., 3pin connector |
E-75/8 currently n/a |
SLE® |
T801 Monitor |
E-15/5 |
Spacelabs® |
Oxygen sensor015-0285-00, 90513 |
E-15/5 |
Spacelabs® |
Oxygen sensor 015-0132-03, 90514 gas analyzer |
E-17/A2 |
Sun Medical® |
|
E-33/0 |
Taema® |
Alys, Clarys, YR010100 |
E-15/5 |
Taema® |
Cesar (new) |
E-17/A2 |
Taema® |
Eole, Cesar |
E-17/J |
Taema® |
YR 049700, Cesar 2, Horus |
E-17/M |
Taema® |
KV050501, Oxy2100 |
E-33/0 |
Taema® |
YR 010100, Alys, Claris |
E-15/5 |
Teledyne® |
C-41131 (R15) |
E-15/0 |
Teledyne® |
C-61339 (R23MED) |
E-15/2 |
Teledyne® |
R30MED |
E-15/4 |
Teledyne® |
TED-AX300 (R17MED, R17MEDV) |
E-15/5 |
Teledyne® |
R22MED |
E-17/A2 |
Teledyne® |
B-62321 (R24MED) |
E-17/M |
Teledyne® |
R24MED |
E-17/M |
Teledyne® |
R29MED |
E-25/0 |
Teledyne® |
C1R (B 39022) |
E-33/1 |
Teledyne® |
R13MED |
E-55/0 |
Teledyne® |
R15MED |
E-15/0 |
Teledyne® |
R26MED |
E-15/5 |
Teledyne® |
R32MED |
ask Nuova |
Teledyne® |
C2R (B 39023) |
E-33/0 |
Teledyne® |
Class C1, T1/T2, TED160, 190 |
E-33/0 |
Teledyne® |
AX300/MX300 |
E-15/5 |
Teledyne® |
R-36 |
E-17/A2 |
Teledyne® |
A51327 (T-7) TED60T, 191T,200T, 200T |
E-77/0 |
Vapotherm® |
Precision Flow |
E-75/1 |
Vascular Technology® |
100352 |
E-15/0 |
Vascular Technology® |
101372 |
E-15/2 |
Vascular Technology® |
103100 |
E-17/M |
Vascular Technology® |
103101 |
E-33/0 |
Vascular Technology® |
103102 |
E-77/0 |
Vascular Technology® |
103103 |
E-33/1 |
Vasular Technology® |
101272 |
E-15/0 |
Vasular Technology® |
100580 |
E-17/J |
Ventronix® |
5525, 5528, 5529 |
E-33/1 |
Ventronix® |
5500, 5570, 5575, 5584, 5590, 5595 |
E-55/0 |
Versamed® |
I-Vent 201AB,HC,IC, IC/AB |
E-16/HTT |
Viasys® (CAREFUSION®) |
6400/8400/VIP Ventilator Sensor P/N 60030 |
E-17/J |
Viasys® (CAREFUSION®) |
AVEA/Infant Flow SiPap |
E-17/C |
Viasys ® (CAREFUSION®) |
VELA |
E-75/4 currently n/a |
Viasys® (CAREFUSION®) |
2000 older model |
E-75/6 currently n/a |
VTI® |
VT1272, 101272, 100352 |
E-15/0 |
VTI® |
101372, 100352 |
E-17/J |
VTI® |
103100 |
E-17/M |
THIẾT BỊ Y TẾ
MÁY X QUANG
MÁY NỘI SOI
MÁY ĐIỆN TIM, SỐC TIM
MONITOR THEO DÕI
DAO MỔ ĐIỆN
MÁY ĐIỆN NÃO
ĐÈN SOI, ĐIỀU TRỊ VÀNG DA
MÁY SIÊU ÂM
MÁY SOI CỔ TỬ CUNG
TỦ HẤP SẤY TIỆT TRÙNG
MÁY TẠO OXY, KHÍ DUNG
MÁY HÚT RỬA DẠ DÀY
MÁY ĐO HUYẾT ÁP
ĐÈN MỔ TIỂU PHẪU & PHẪU THUẬT
BƠM TIÊM ĐIỆN - BƠM TRUYỀN DỊCH
MÁY XÉT NGHIỆM
HỆ THỐNG LÀM ẤM BỆNH NHÂN
HỆ THỐNG KHÍ Y TẾ
VẬT LÝ TRỊ LIỆU & PHỤC HỒI CHỨC NĂNG
PHỤ KIỆN Y TẾ
BÁN HÀNG TOÀN QUỐC
Online 24/24
Call, SMS, Zalo
Hotline: 0987.315.855
Huyền: 086.8888.927
Hoàng: 033.2637.099
Thúy: 0986.369.033